| Data Téknis Kingflex | |||
| Properti | Unit | Nilai | Métode Tés |
| Rentang suhu | °C | (-50 - 110) | GB/T 17794-1999 |
| Rentang kapadetan | Kg/m3 | 45-65Kg/m3 | ASTM D1667 |
| Permeabilitas uap cai | Kg/(mspa) | ≤0.91×10﹣¹³ | DIN 52 615 BS 4370 Bagian 2 1973 |
| μ | - | ≥10000 |
|
| Konduktivitas Termal | W/(mk) | ≤0.030 (-20°C) | ASTM C 518 |
| ≤0.032 (0°C) | |||
| ≤0.036 (40°C) | |||
| Rating Seuneu | - | Kelas 0 & Kelas 1 | BS 476 Bagian 6 bagian 7 |
| Indéks Sebaran Seuneu sareng Pengembangan Haseup |
| 25/50 | ASTM E 84 |
| Indéks Oksigén |
| ≥36 | GB/T 2406, ISO4589 |
| Panyerepan Cai,% dumasar Volume | % | 20% | ASTM C 209 |
| Stabilitas Diménsi |
| ≤5 | ASTM C534 |
| Résistansi jamur | - | Saé | ASTM 21 |
| Résistansi ozon | Saé | GB/T 7762-1987 | |
| Tahan ka UV sareng cuaca | Saé | ASTM G23 | |
Konduktivitas rendah & konduktivitas panas
Insulasi pipa sél katutup Dicirikeun ku struktur sél anu katutup sagemblengna sareng dumasar kana karét sintétis anu luhur
Pipa busa karét tiasa maénkeun peran hiasan dina pipa sareng peralatan. Penampilan pipa insulasi karét-plastik lemes sareng rata, sareng penampilan sacara umum éndah.
Tahan api anu saé
Tabung insulasi ieu didamel tina NBR sareng PVC. Éta henteu ngandung lebu serat, benzaldehida sareng Klorofluorokarbon. Leuwih ti éta, éta gaduh konduktivitas & konduktivitas panas anu handap,
Tahan kalembaban anu saé sareng Tahan seuneu.
Ukuran anu béda-béda sayogi, numutkeun sarat konsumén
Loba dipaké pikeun insulasi pipa jeung saluran
Harga kami kompetitif pisan di pasar